Engine and gearbox (P)

P0006: Fuel Shutoff Valve A Circuit Low

The control voltage for the fuel shutoff valve A is lower than expected. This is often due to a short to ground or a low-resistance fault in the solenoid circuit.

Checked by a licensed car technician ยท last reviewed 29 September 2026

Symptoms

  • Engine may not start
  • Engine stalls unexpectedly
  • Check engine light is on

Common causes

  1. Wiring shorted to ground
  2. Shutoff solenoid internal short
  3. Corroded connector pins

How to check it yourself

  1. Inspect wiring for damage or shorts
  2. Check connector pins for corrosion
  3. Test the shutoff solenoid for internal faults

Can I keep driving?

The car should not be driven if the engine stalls or fails to start.

General guidance, not a professional inspection. Confirm faults with measurements before buying parts, and use a qualified mechanic for brakes, steering, fuel leaks, airbags, and other safety-critical work. Terms and disclaimer